~V|CYPE INGENIEROS, S.A.|FIEBDC-3/2002|wservigen_bra||ANSI| ~K|\2\3\3\2\2\2\2\BRL|3.00\13.00\6.00\\17.00|| ~X||INFORMACION_GENERADOR\Parâmetros de configuração do Gerador de preços\\INFORMACION_SEGSALUD_GENERADOR\Segurança e saúde\\| ~X|obra##|INFORMACION_GENERADOR\0a000100000e001d008e010000ffffffff00000000070100c80000000000000000001440000000000000000000000030a14006000000010000000000000000407f40010001000000020001000100010002000100020001000100000000000000000000000000000000000000000000000000004940000000000000000002000000010101010000070000000000c0624000000000004ced40333333333333c33f000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000100000000000010400000000000002440000000000000264000000000000026400000010000000101010100000000010000010001000000000001000000000001000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000\\| ~C|mt37sve010d|Un|Registro de esfera de latão niquelado para enroscar de 1".|36.28||3| ~X|mt37sve010d|INFORMACION_GENERADOR\#U0001003bdf4f8d976eb23f000000000000e83f0000000000000000333333333333e33f0000000000000000333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f000000000101000000000000000000000000000000000000000000000000010000000105006c61746f6e0100000000333333333333134000000000001c9540009a9999999999b93f01000000010a00706170656c5f6361727401000000003bdf4f8d976eb23f00000000001c9540009a9999999999b93f\\| ~C|mt42dai322c|Un|Bomba de calor aerotérmica, ar-água, para aquecimento, para gás R-32, com compressor swing, alimentação monofásica (230V/50Hz), potência calorífica 12 kW, e consumo elétrico 3,39 kW, com temperatura de bulbo seco do ar exterior 7°C e temperatura de saída da água 45°C, potência calorífica 12 kW, COP 4,87 e consumo elétrico 2,53 kW, com temperatura de bulbo seco do ar exterior 7°C e temperatura de saída da água 35°C, dimensões 870x1378x460 mm, diâmetro de ligação das tubulações de água 1".|55370.38||3| ~X|mt42dai322c|INFORMACION_GENERADOR\#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\\| ~C|mt42www080|Un|Kit de amortecedores anti-vibração de piso, formado por quatro amortecedores de borracha, com os correspondentes parafusos, porcas e arruelas.|53.57||3| ~C|%|%|Custos diretos complementares|0.00||0| ~C|ICV045|Un|Unidade ar-água, bomba de calor aerotérmica, para aquecimento.|0.00||0| ~T|ICV045|Bomba de calor aerotérmica, ar-água, para aquecimento, para gás R-32, com compressor swing, alimentação monofásica (230V/50Hz), potência calorífica 12 kW, e consumo elétrico 3,39 kW, com temperatura de bulbo seco do ar exterior 7°C e temperatura de saída da água 45°C, potência calorífica 12 kW, COP 4,87 e consumo elétrico 2,53 kW, com temperatura de bulbo seco do ar exterior 7°C e temperatura de saída da água 35°C, dimensões 870x1378x460 mm, diâmetro de ligação das tubulações de água 1". Inclusive elementos anti-vibratórios de piso. Totalmente montada, ligada e colocada em funcionamento pela empresa instaladora para a verificação do seu correto funcionamento. Inclui: Implantação da unidade. Colocação e fixação da unidade e respectivos acessórios. Ligação com as redes de abastecimento de água, elétrica e de coleta de condensados. Colocação em funcionamento. Critério de medição de projeto: Número de unidades previstas, segundo documentação gráfica de Projeto. Critério de quantitativos de obra: Medir-se-á o número de unidades realmente executadas segundo especificações de Projeto. | ~D|ICV045 |mt42dai322c\\1.000 \mt37sve010d\\2.000 \mt42www080\\1.000 \%\\0.020 \| ~X|ICV045|INFORMACION_GENERADOR\0d01010600494356303435010000000000010000000007006963765f30343500120000000000000000000000000000000000000000000000000000000000000000000000000000000100000000000000000000000000000000000000000000000000000000000000000000000000000000000000713d0ad783b0e14001000000000000000000000000000000e83f0000000000000000333333333333e33f0000000000000000333333333333e33f00000000000000009a9999999999f13f0000000000000000333333333333e33f000000000101000000000000000000000000000000000000000000000000000000000000000000\\| ~C|I#||Instalações|0.00||0| ~D|I# |IC#\\1.000 \| ~C|IC#||Aquecimento, refrigeração, climatização e água quente|0.00||0| ~D|IC# |ICV#\\1.000 \| ~C|ICV#||Unidades centrais para aquecimento, refrigeração, climatização e água quente|0.00||0| ~D|ICV# |ICV045\\0.000 \| ~M|ICV\ICV045|1\1\1\1\|0.000|| ~C|obra##||BC3|0.00||0| ~D|obra## |I#\\1.000 \|